IRTUM – Institutional Repository of the Technical University of Moldova

Problemele utilizării mașinilor frigorifice cu absorbție și perspectivele implementării

Show simple item record

dc.contributor.advisor CARTOFEANU, Vasile
dc.contributor.author BUDURIN, Nicolae
dc.date.accessioned 2025-02-12T13:07:47Z
dc.date.available 2025-02-12T13:07:47Z
dc.date.issued 2025
dc.identifier.citation BUDURIN, Nicolae. Problemele utilizării mașinilor frigorifice cu absorbție și perspectivele implementării. Teză de master. Programul de studiu Inginerie Mecanică. Conducător ştiinţific CARTOFEANU Vasile. Universitatea Tehnică a Moldovei. Chișinău, 2025. en_US
dc.identifier.uri https://repository.utm.md/handle/5014/29520
dc.description Fişierul ataşat conţine: Adnotare, Annotation, Cuprins, Introducere, Bibliografie. en_US
dc.description.abstract Obiectivul tezei: analiza constructiv-funcțională a mașinilor frigorifice cu absorbție și perspectivele implementării. În lucrare au fost propuse și dezvoltate soluții schematice pentru complexul de mașini frigorifice cu absorbție cu pompă de căldură încorporată și colectoare solare. Au fost efectuate calcule ale circuitelor AHM-TNU-SolKol și comparații ale unor astfel de scheme cu AHM cu apă caldă într-o singură etapă și în două trepte. A fost proiectat și dezvoltat un banc de testare experimental AHM-TNU în scopuri de cogenerare pentru a studia caracteristicile energetice și termice ale echipamentelor de alimentare cu căldură și răcire. A fost efectuat un studiu al modurilor de funcționare ale complexului AHM-TNU și a fost efectuată o analiză a eficienței energetice a acestora. S-a confirmat empiric că, odată cu implementarea soluțiilor tehnice propuse, coeficientul de refrigerare al ACM atinge valorile de 0,831 (cu încălzirea electrică tradițională a generatorului său - 0,3). en_US
dc.description.abstract The objective of the thesis: the constructive-functional analysis of absorption refrigerating machines and the prospects of implementation. In the work schematic solutions for the complex of absorption chillers with built-in heat pump and solar collectors were proposed and developed. Calculations of the AHM-TNU-SolKol-SolKol circuits and comparisons of such schemes with single-stage and two-stage hot water AHMs were carried out. An experimental AHM-TNU experimental AHM-TNU test bench for cogeneration purposes was designed and developed to study the energy and thermal characteristics of heat supply and cooling equipment. A study of the operating modes of the AHM-TNU complex was carried out and an analysis of their energy efficiency was performed. It was empirically confirmed that, with the implementation of the proposed technical solutions, the cooling coefficient of the ACM reaches the values of 0.831 (with traditional electric heating of its generator - 0.3). en_US
dc.language.iso ro en_US
dc.publisher Universitatea Tehnică a Moldovei en_US
dc.rights Attribution-NonCommercial-NoDerivs 3.0 United States *
dc.rights.uri http://creativecommons.org/licenses/by-nc-nd/3.0/us/ *
dc.subject mașini frigorifice en_US
dc.subject eficiență energetică en_US
dc.subject energie termică en_US
dc.subject refrigerating machines en_US
dc.subject energy efficiency en_US
dc.subject thermal energy en_US
dc.title Problemele utilizării mașinilor frigorifice cu absorbție și perspectivele implementării en_US
dc.title.alternative Problems of utilization of absorption refrigeration machines and perspectives of implementation en_US
dc.type Thesis en_US